Experiments/EdgePlasmaPhysics/ParticleFlux/RakeProbe/1114ShotToShotMeasurement/Sessions/1114Intro/index

Langmuir probe VA characteristics measurement of the standard GOLEM tokamak plasma

Aim: to measure VA characteristics on the shot to shot basis.

##Experimental setup

Rake probe description

##Theory

###Initial configuration:

  • Date: Afternoon 261114
  • LP position of 1st pin from the vessel center \(LP_{pos}=107\) mm,
  • \(V_{bias}\) off,
  • \(R=100\) Ohm:
  • LP orientation: pins ahead SouthEast (in the port direction), i.e. probe is oriented perpendicularly to the magnetic field lines
  • Discharge setup: –UBt 800 –Ucd 500 –Tcd 10000 –Tres 2000 –pressure 1 –preionization 4
  • Preionization: ECR wave
  • \(V_{bias}\) measured with 1:100 divider

###Minutes of the experiment:

Aim Shot(s) Comments
Reference shot #17717
Switching on \(V_{bias}\) to ~ 10V #17718 OK, \(V_{bias}\) goes to ~0.1V
Lp to position \(LP_{pos}\) = 54 mm #17719 \(I_{sat}\) too high ~ 100 mA
Galvanic insulation implemented for V_bias power supply #17720 Satisfactory, no problem
Since \(I_{sat}\) is too high,
Let’s decrease R to 50 Ohm
#17721 Better, but still \(V_R\) ~9V
Since \(I_{sat}\) is still too high,
Let’s take out LP to position 68 mm
#17722 to #17726 fails
#17727 OK No effect, still \(V_R\) ~9V
HS discussion: configuration OK
reverse \(V_{bias}\) polarity to -10 V to measure \(I_{is}\)
#17728 to #17733 fails
#17734 OK Hopefully good result
\(V_{bias}\) = {-20,-30,-40} V #17735,#17736,#17737 OK, ready for scan
Scan \(V_{bias}\) = {-40,-35,-30,-25,-20,-15,-10,-5,0,1,2,3,4,5,6,7,8,9,10,12} V From #17739 to #17762 see Figs. 1, 2, 3, 4

###Final experiment configuration:

  • LP position of 1st pin from the vessel center \(LP_{pos}=68\) mm,
  • \(V_{bias}\) from -40V (#17739) to 12V (#17762),
  • \(R=50\) Ohm:
  • LP orientation: pins ahead SouthEast (in the port direction) i.e. probe is oriented perpendicularly to the magnetic field lines
  • Discharge setup: –UBt 800 –Ucd 500 –Tcd 10000 –Tres 2000 –pressure 1 –preionization 4
  • Preionization: ECR wave
  • \(V_{bias}\) measured with 1:100 divider
  • Length of pin: 2 mm, diameter of the pin: 0.7 mm => pin surface ~ 3.140.7210^-6 m^2 ~ 4.410^-6 m^2

##Reference shot #17743

Reproducibility of the GOLEM tokamak discharge from #17739 to #17762


\(I_{p}\) scan - alltogether (jpg, svg,canvas,script)

##Raw experimental data


Fig.1: \(V_{bias}\) scan - alltogether (jpg, svg,canvas,script)


Fig.2: \(V_{bias}\) scan - ion side (jpg, svg,canvas,script)


Fig.3: \(V_{bias}\) scan - electron side (jpg, svg,canvas,script)


Fig.4: \(V_{bias}\) scan - alltogether \(U_{bias}\) (jpg, svg,canvas,script)

##Analysis ### Raw data - VA characteristics at specific time with \(10\mu s\) averaging.

VA characteristics fit

This video in avi format

Resulting dependeces

Discussion

  • The reason for the VA char vanish in the end of the discharge could be fact, that the GOLEM plasma is normally moving up as can be seen here (#11405):

Note the rake probe seen in the photo.

Data access

Codes used

References:

EEDF

  • [Annette Meiners @COMSOL: Electron Energy Distribution Function](http://www.comsol.com/blogs/electron-energy-distribution-function/)